Description
Product Overview
Introducing the Exitex fire-rated packers, expertly engineered to provide essential support between the architrave of the door and the wall. These packers are crucial for maintaining safety during a fire, ensuring that your doorset installation adheres to the highest standards.
Installation Guidelines
For optimal performance, the installation of the doorset must comply with BS476-22 / BS-EN 1634-1 standards, as well as the manufacturer's guidelines. It is imperative that fire-rated packers are utilized alongside foam to enhance their effectiveness.
Key Specifications
-
Fire Resistance: Tested for 30 and 60 minutes in accordance with BS-EN 1634-1 and BS476-22.
-
Testing Conditions: Evaluated using full-size single and double door sets, not linear gaps.
-
Material Compatibility: Successfully tested with softwood, MDF, and hardwood frame sections.
-
Gap Tolerance: Effective for gaps ranging from 7mm to 30mm.
-
Retro-fit Capability: Designed for retro-fit scenarios, facilitating rectification applications.
-
Available Sizes: Offered in 1mm, 3mm, and 5mm thicknesses, all color-coordinated for aesthetic integration.
Ensure your installations are compliant and safe with Exitex fire-rated packers, the reliable choice for fire safety solutions.